Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Diagnostics (Basel) ; 13(9)2023 Apr 28.
Article in English | MEDLINE | ID: covidwho-2313270

ABSTRACT

(1) Background: Cardiac electrotherapy is developing quickly, which implies that it will face a higher number of complications, with cardiac device-related infective endocarditis (CDRIE) being the most frequent, but not the only one. (2) Methods: This is a retrospective case study followed by a literature review, which presents a patient with a rare but dangerous complication of electrotherapy, which could have been prevented if modern technology had been used. (3) Results: A 34-year-old female was admitted with suspicion of CDRIE based on an unclear echocardiographic presentation. However, with no signs of infection, that diagnosis was not confirmed, though an endocardial implantable cardioverter-defibrillator (ICD) lead was found folded into the pulmonary trunk. The final treatment included transvenous lead extraction (TLE) and subcutaneous ICD (S-ICD) implantation. (4) Conclusions: With the increasing number of implantations of cardiac electronic devices and their consequences, a high index of suspicion among clinicians is required. The entity of the clinical picture must be thoroughly considered, and various diagnostic tools should be applied. Lead dislocation into the pulmonary trunk is an extremely rare complication. Our findings align with the available literature data, where asymptomatic cases are usually effectively treated with TLE. Modern technologies, such as S-ICD, can effectively prevent lead-related problems and are indicated in young patients necessitating long-term ICD therapy.

2.
Pacing Clin Electrophysiol ; 45(6): 807-810, 2022 06.
Article in English | MEDLINE | ID: covidwho-1832218

ABSTRACT

In the era of coronavirus disease 2019 (COVID-19), the management of cardiac implantable electronic devices infections with concomitant viral infection has not been completely defined yet. In this explorable context, we report the first experience of a Cardiac resynchronization therapy with defibrillator (CRT-D) implantation after transvenous lead extraction for endocarditis in a COVID-19 patient. We describe both the measures and procedures implemented to reduce the cross-infection in the operating room and our clinical practice to improving procedure effectiveness on patient care.


Subject(s)
COVID-19 , Cardiac Resynchronization Therapy , Defibrillators, Implantable , Endocarditis , Heart Diseases , Cardiac Resynchronization Therapy Devices , Device Removal/methods , Humans , Retrospective Studies , SARS-CoV-2 , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL